You are offline. What you type is kept on this device; saving to JobBosh resumes when the connection is back.
Historic rate books
Reference only. Scanned schedules of rates supplied by the owner (Adobe Scan for iOS). Edition, publisher and base year are NOT stated in the scans and have not been confirmed: every figure here is a HISTORIC reference rate, never a current price. Base and Op's columns are kept separately where the book prints both. Parsed rows: 583 carpentry-joinery, 378 finish-paint-clear, 206 groundworks, 351 guttering-plumbing, 190 roofing; 99 rows are in the review queue (unreadable in the scan) and are not shown as figures.
| Code | Trade | Description | Unit | Base / Op's (historic) | Read |
|---|---|---|---|---|---|
| 70101 | Carpentry and joinery | Shed : Supply and install proprietary storage shed (PC Sum for Supply £300 approximate plan size 2400x1800mm complete with door, all ironmongery, locks etc, ehed fixed to and Including 150mm concrete elab lald on and Inc | IT | 611.88 | read |
| 70102 | Carpentry and joinery | Shed . Supply and Install proprietary storage shed (PC Sum for Supply £300 approximate plan size 2400x1800mm complete with door, all Ironmongery, locks etc., shed fixed to existing concrete or precast concrete hardstandi | IT | 498.6 | read |
| 70105 | Carpentry and joinery | Door : Renew shed or bin store door with any size 40mm thick single softwood matchboard ledged and braced door with 169x20mm ledges and 106x20mm braces covered on face with 20mm tongued, grooved and v jointed boarding, i | NO | 135.25 | read |
| 70107 | Carpentry and joinery | Door Renew shed or bin store door with any size 40mm thick single softwood matchboard framed, ledged and braced door with 169x20mm ledges and 106x20mm braces covered on face with 20mm tongued, grooved and v jointed board | NO | 154.75 | read |
| 70109 | Carpentry and joinery | Shed Lock : Renew rimlock, keep and set of rimlock furniture to shed or bin store door, including altering door as necessary for new lock and housing out existing frame as necessary | NO | 46.22 | inferred |
| 70111 | Carpentry and joinery | Shed Door • Renew or supply and fix 50mm galvanised 'Squire' 440 or other equal and approved padlock to shed or bin store door, supply two keys and hand to Tenant or Contract Administrator. | NO | 21.49 | inferred |
| 70113 | Carpentry and joinery | Shed Door : Renew any type of hasp and staple to shed or bin store door. | NO | 12.28 | read |
| 70115 | Carpentry and joinery | Shed Door Renew any type of hasp, staple and 50mm galvanised 'Squire' or other equal and approved padlock to shed or bin store door, supply two keys and hand to Tenant or Contract Administrator. | NO | 30.42 | read |
| 301103 | Carpentry and joinery | Joist: Renew with pressure impregnated sawn softwood floor joist NE. 100mm deep to match existing, cut out and clear away existing, cut new joist to length and fix including all packings, cleats, hangers. noggins, solid | LM | 7.53 | read |
| 301107 | Carpentry and joinery | Joist • Renew with pressure impregnated sawn softwood floor joist N.E. 225mm deep to match existing cut out and clear away existing, cut new joist to length and fix including all packings, cleats, hangers, noggins, solid | LM | 13.75 | read |
| 301109 | Carpentry and joinery | Joist : Level joist by inserting packings including take up floorboards and refix, make good any finishes disturbed, remove and refix any carpets and furniture. (measured per joist), (not to be claimed in conjunction wit | NO | 20.24 | inferred |
| 301122 | Carpentry and joinery | Floor : Strip out defective timber floor complete with any redundant service installation attached or passing through floor, demolish sleeper walls down to sub- floor level, make good all works disturbed, clear away debr | SM | 10.81 | read |
| 301123 | Carpentry and joinery | Floor : Strip out existing floor and sleeper walls, remove void debris, construct half brick sleeper walls in cement mortar (1 : 3) on concrete foundation including excavation and disposal and lay new softwood floor comp | SM | 100.08 | read |
| 301125 | Carpentry and joinery | Floor: Renew softwood floor comprising 22mm square edge boards, N.E. 50x125mm joists and N.E. 50x100mm wall plates including dpc, all in pre-treated timber, complete with galvanised Joist hangers, cut and primed in, clea | SM | 62.28 | read |
| 301127 | Carpentry and joinery | Floor: Renew softwood upper floor comprising 22mm square edge boards N E. 50x175mm joists and N.E. 50x100mm wall plates including dpc, 25x50mm strutting, all In pre-treated timber. complete with galvanised joist hangers, | SM | 65.18 | read |
| 301129 | Carpentry and joinery | Floor : Construct softwood floor comprising 22mm square edge boards, N.E. 50x125mm joists and N.E. 50x100mm wall plates Including dpc, In pre-treated timber, complete with galvanised joist hangers, cut and primed in, cle | SM | 53.27 | read |
| 301131 | Carpentry and joinery | Floor: Construct softwood upper floor comprising 22mm square edge boards, N.E. 50x175mm joists and N.E. 50x100mm wall plates including dpc, 25x50mm strutting, all in pre-treated timber, Including trimming to openings In | SM | 56.17 | inferred |
| 301201 | Carpentry and joinery | Floor : Strip out defective timber floor complete with any redundant service installation attached or passing through floor In conjunction with dpc wall treatment, clear B:Nay debris to approved tip. | SM | 6.44 | read |
| 301203 | Carpentry and joinery | Floor : Clear all existing debris from under floor void in conjunction with dpc wall treatment, clear away debris to approved tip. | CM | 20.34 | read |
| 301205 | Carpentry and joinery | Floor : Remove remnants of any joists N.E. 150mm deep and other timber from walls and brick up any pockets remaining, clear fNiay debris to approved tip. | NO | 4.3 | read |
| 301207 | Carpentry and joinery | Floor: Remove remnants of any joists and other timbers over 150 and N.E. 300mm deep from walls and brick up any pockets remaining, clear fNiay debris to approved. | NO | 5.84 | read |
| 301301 | Carpentry and joinery | Partition : Supply and erect or renew stud partition compnsing N.E. 50x100mm sole and head plate, noggins and studs foced with nails or plugged and screwed to walls, and pack out and scribe, 12.5mm taper edged plasterboa | SM | 46.41 | read |
| 301303 | Carpentry and joinery | Partition· Supply and erect or renew stud partition comprising N.E. 50x100mm sole and head plate, noggins and studs fixed with nails or plugged and screwed to walls, and pack out and scribe, 12.5mm butt jointed plasterbo | SM | 52.76 | read |
| 301305 | Carpentry and joinery | Partition: Supply and install insulation infill NE. 100mm thick to stud partition. | SM | 3.72 | read |
| 301307 | Carpentry and joinery | Partition : Supply and install sound insulation infill 75mm thick to stud partition. | SM | 7.68 | read |
| 301311 | Carpentry and joinery | Partition : Supply and erect or renew proprietary metal stud partition comprising sole and head plate, noggins and studs fixed with nails or plugged and screwed to walls, and pack out and scribe, 12 5mm taper edged plast | SM | 30.45 | read |
| 301313 | Carpentry and joinery | Partition : Supply and erect or renew propnetary metal stud partition comprising sole and head plate, noggins and studs fixed with nails or plugged and screwed to walls, and pack out and scribe, 12.5mm butt jointed plast | SM | 35.96 | read |
| 301315 | Carpentry and joinery | Partition: Fill In existing opening in stud partition with N.E. 50x100mm sole and head plate, noggins and studs fixed with nails or plugged and screwed to walls, and pack out and scribe, 12.5mm taper edged plasterboard s | SM | 61.79 | read |
| 301317 | Carpentry and joinery | Partition . Cut and fonn opening In existing stud partition plastered both sides, frame up opening with 50x100mm head plate, noggins and studs fixed with nails or plugged and screwed to walls, and pack out and scribe, ma | IT | 67.17 | read |
| 301401 | Carpentry and joinery | Larder : Remove, set aside, store and later refix built insitu, studded larder or storage unit in conjunction with specialist treatment, reinstate entire unit including make good any damage caused whilst dismantling. | IT | 26.98 | read |
| 301403 | Carpentry and joinery | Wall : Renew any non structural partition with softwood studding faced both sides with skim coated 12.Sm plasterboard and skirting, refix any fittings, make good to adjacent surfaces, all In conjunction with specialist t | SM | 59.79 | read |
| 301501 | Carpentry and joinery | Plate : Renew pressure impregnated sawn softwood wall plate N.E. 75x100mm, bedded in cement mortar (1 : 3) and apply preservative to cut ends, clear away debris to approved tip. | LM | 7.01 | read |
| 301503 | Carpentry and joinery | Plate: Renew pressure Impregnated sawn softwood wall plate N.E. 75x100mm, bedded in cement mortar (1 : 3) and apply preservative to cut ends on and including polypropylene damp proof course 138mm girth, clear away debris | LM | 8.86 | read |
| 301701 | Carpentry and joinery | Rafter: Renew with pressure impregnated sawn softwood rafter/roof JOISt, N.E. 175mm deep to match existing in roof apace, cut new rafter or roof joist to length, apply preservative to cut ends, cut out and make good to b | LM | 7.88 | read |
| 301703 | Carpentry and joinery | Collar/Strut: Renew with pressure impregnated sawn softwood collar or strut, N.E. 175mm thick to match existing in roof space, cut new collar to length, apply preservative to cut ends, and cut out and make good brickwork | LM | 10.46 | read |
| 301901 | Carpentry and joinery | Hanger : Renew galvanised joist hanger, cut out, bed In mortar and make good br1ckwork, renew In conjunction with joist repairs. | NO | 5.54 | read |
| 301903 | Carpentry and joinery | Hanger : Cut out and insert galvanised steel joist hanger to correct floor alignment, bed in mortar, pin, make good brickwork, renew In conjunction with floor or joist repairs. | IT | 7.6 | read |
| 303001 | Carpentry and joinery | Fascia/Barge: Renew fascia or barge with preservative treated softwood, N.E. 300mm wide, fixed to roof timbers, apply preservative to cut ends, remove and refix rainwater goods and any cabling, adjust roof tiles and felt | LM | 23.54 | read |
| 303003 | Carpentry and joinery | Fascia/Barge : Renew fascia or barge with WPB external quality plywood, N.E. 300mm wide fixed to roof timbers, apply preservative to cut ends, remove and refix rainwater goods and any cabling, adjust roof tiles and felt, | LM | 21.74 | read |
| 303005 | Carpentry and joinery | Fascia/Barge : Renew fascia or bargeboard with proprietary PVCu board N.E. 300mm wide fixed to roof timbers, remove and refix rainwater goods and any cabling, remove existing board, adjust roof tiles and felt, renewal of | LM | 17.99 | read |
| 303007 | Carpentry and joinery | Soffrt: Renew soffit board with treated softwood N.E. 450mm wide including renew noggins as necessary fixed to roof timbers and refix cables and decorate to match existing | LM | 23.12 | read |
| 303009 | Carpentry and joinery | Soffit • Renew soffit board with WPB plywood N.E. 450mm wide including renew noggins as necessary fixed to roof timbers and refix cables and decorate to match eXlsting. | LM | 22.99 | read |
| 303011 | Carpentry and joinery | Soffit : Renew soffit board with masterboard N.E. 450mm wide Including renew noggins as necessary fixed to roof timbers and refix cables and decorate to match existing. | LM | 30.9 | read |
| 303013 | Carpentry and joinery | Soffit : Renew soffrt board with PVCu board N.E. 450mm wide including remove existing, renew noggins as necessary and fix new board to roof timbers and refix cables. | LM | 17.55 | read |
| 303015 | Carpentry and joinery | Fascla/Soffrt/Barge: Refix any size fascia, soffit or bargeboard to existing roof timbers including remove/refix rainwater goods and cabling as necessary, renewal of support battens, all cutting and packing and make good | LM | 16.07 | read |
| 303017 | Carpentry and joinery | Boxed End : Renew boxed end to fascia and soffit including renewing as required timber supports, new WPB plywood soffit, fascia etc and all cutting and shaping and jointing to existing fascias, soffrts etc., and decorate | NO | 30.07 | inferred |
| 303019 | Carpentry and joinery | Boxed End : Renew boxed end to fascia and soffit including renewing as required timber supports, new proprietary PVCu board soff'rt, fascia etc. and all cutting and shaping and jointing to existing fascias, soff'rts etc. | NO | 28.68 | read |
| 305101 | Carpentry and joinery | Flooring: Renew any flooring with 19mm WBP plywood including denial joists, clear away debris to approved tip, punch in nails, level to existing and make good including additional noggins/support battens as required. | SM | 26.23 | read |
| 305501 | Carpentry and joinery | Flooring : Supply and lay 3.2mm floonng grade hardboard nailed to ex1st1ng floorboard at 150mm centres with wired nails and level as necessary. | SM | 6.16 | read |
| 305701 | Carpentry and joinery | Floorboard : Renew to match existing any flooring with 19mm tongued and grooved or square edged flooring In area N.E. 1.00sm, Including denall joists, clear away debris to approved tip, punch In nails, level to existing | IT | 33.47 | read |
| 305703 | Carpentry and joinery | Floorboard : Renew to match existing any flooring with 19mm tongued and grooved or square edged flooring in area over 1 OOsm including denail joists, clear away debris to approved tip, punch in nails, level to existing a | SM | 32.22 | read |
| 305705 | Carpentry and joinery | Floorboard : Remove and later reflx any boards, including denaII joists clear away debris to approved tip, punch in nails, level to existing and make good including any extra noggins required. | LM | 2.61 | read |
| 305706 | Carpentry and joinery | Floorboard : Screw down any width loose floorboards in any room N.E. 5.00sm Including providing fixing batten to side of joist where end of board is unsupported (Per room) | IT | 3.19 | read |
| 305707 | Carpentry and joinery | Floorboard : Screw down any width loose floorboards in any room over 5.00 and N.E. 10.00sm including providing fixing batten to side of joist where end of board is unsupported(Perroom) | IT | 4.79 | read |
| 305709 | Carpentry and joinery | Preservative : Prepare and brush apply two coats of approved preservative to general surfaces of flooring. | SM | 4.61 | read |
| 305801 | Carpentry and joinery | Floor : Take up floor boards to facilitate joist renewals, and apply chemical insecticide treatment to boards, joists and plates, on completion refix floorboards including up to 5% floorboard renewal. | SM | 22.36 | read |
| 305804 | Carpentry and joinery | Dwelling : Take up all floorboards of any type, treat with insecticide all floorboards, joists, plates, bridging, other timbers, on completion refix floorboards including up to 10% floorboard renewal. | IT | 686.54 | read |
| 305805 | Carpentry and joinery | Floor . Remove any type of floorboards and treat with three full brush coats of preservative to BS 5707 Type F all floorboards, joists, plates, bridging and other floor timbers, on completion refix floorboards including | SM | 31.4 | read |
| 305806 | Carpentry and joinery | Dwelling : Take up all floorboards of any type, treat with 3 coats of preservative to BS 5707 Type F, all floorboards, joists, plates, bridging, other timbers, on completion refix floorboards Including up to 10% floorboa | IT | 782.42 | inferred |
| 305808 | Carpentry and joinery | Dwelling : Provision of 30 year insurance backed guarantee for floor preservation treatment. | IT | 52.5 | read |
| 305810 | Carpentry and joinery | Dwelling : Take up 20% of floorboards as necessary to 1 bed dwelling to facilitate access for timber preservative treatment by Specialist, refix floorboards, allow for up to 50% renewal as required, punch in nail heads, | IT | 326.04 | read |
| 305816 | Carpentry and joinery | Dwelling : Take up 20% of floorboards as necessary to 2 bed dwelling to facilitate access for timber preservative treatment by Specialist, refix floorboards, allow for up to 50% renewal as required, punch in nail heads, | IT | 381.09 | read |
| 305818 | Carpentry and joinery | Dwelling : Take up 20% of floorboards as necessary to 3 bed dwelling to facilitate access for timber preservative treatment by Specialist, refix floorboards, allow for up to 50% renewal as required, punch in nail heads, | IT | 436.03 | inferred |
| 305820 | Carpentry and joinery | Dwelling : Take up 20% of floorboards as necessary to 4 bed dwelling to facilitate access for timber preservative treatment by Specialist, refix floorboards, allow for up to 50% renewal as required, punch in nail heads, | IT | 543.74 | read |
| 305822 | Carpentry and joinery | Roof : Remove and set aside Tenants personal affects and stored items in loft area, lift and set aside all roof insulation, clean down all timbers to remove surface dust and debris, treat all accessible structural timber | IT | 151.18 | read |
| 305824 | Carpentry and joinery | Roof : Provision of 30 year insurance backed guarantee for roof timber preservation treatment. | IT | 52.5 | read |
| 305826 | Carpentry and joinery | Dwelling : Take up 20% of floorboards as necessary to 1 bed dwelling to facilitate access for and undertake woodworm treatment by approved Sub-Contractor, refix floorboards, allow for up to 50% renewal as required, punch | IT | 609.54 | read |
| 305828 | Carpentry and joinery | Dwelling • Take up 20% of floorboards as necessary to 2 bed dwelling to facilitate access for and undertake woodworm treatment by approved Sub-Contractor, refix floorboards, allow for up to 500/4 renewal as required, pun | IT | 685.59 | read |
| 305830 | Carpentry and joinery | Dwelling : Take up 20% of floorboards as necessary to 3 bed dwelling to facilitate access for and undertake woodworm treatment by approved Sub-Contractor, refix floorboards, allow for up to 50% renewal as required, punch | IT | 761.53 | read |
| 305832 | Carpentry and joinery | Dwelling : Take up 20% of floorboards es necessary to 4 bed dwelling to facilitate access for and undertake woodworm treatment by approved Sub-Contractor, refix floorboards, allow for up to 50% renewal as required, punch | IT | 911.24 | read |
| 305834 | Carpentry and joinery | Dwelling : Provision of 30 year insurance backed guarantee for woodworm treatment | IT | 52.5 | read |
| 305836 | Carpentry and joinery | Roof : Remove and set aside Tenants personal affects and stored items in loft area, lift and set aside all roof insulation, clean down all timbers to remove surface dust and debris, undertake woodworm treatment by approv | IT | 218.51 | read |
| 305838 | Carpentry and joinery | Roof : Provision of 30 year insurance backed guarantee for roof timber woodworm treatment | IT | 5.25 | inferred |
| 305901 | Carpentry and joinery | Joist Ends : Take up existing floor boarding as necessary, set aside for reuse, take out up to 3 existing joists, apply deep paste treatment to one end of joist, refrx joists, relay floor boarding | IT | 98.67 | read |
| 305903 | Carpentry and joinery | Joist Ends : Take up existing floor boarding as necessary, set aside for reuse, take out over 4 and up to 10 existing joists, apply deep paste treatment to one end of joist, refix joists, relay floor boarding. | IT | 137.71 | read |
| 306001 | Carpentry and joinery | Flooring : Renew wood block floor in patches N.E. 2 00sm including take up existing and clear away, lay new 25mm thick flooring with tongued and grooved joints fixed with adhesive and laid to herring bone pattern includi | IT | 123.38 | read |
| 306003 | Carpentry and joinery | Flooing : Renew wood block floor in patches over 2.00sm including take up existing and clear away, lay new 25mm thick flooring with tongued and grooved joints fixed with adhesive and laid to herring bone pattern includin | SM | 82.26 | read |
| 307101 | Carpentry and joinery | Cladding : Remove existing defective shIplap boarding and renew with 19mm pressure impregnated shiplap boarding in areas N.E. 2.00sm including all labours, fixed to existing framework including renew defective support ba | IT | 59.4 | read |
| 307103 | Carpentry and joinery | Cladding: Remove existing cladding and renew with 19mm pressure impregnated shiplap boarding in areas over 2.00sm including all labours, fixed to existing framework including renew defective support battens and provide a | SM | 34.11 | read |
| 307301 | Carpentry and joinery | Cladding : Remove existing defective feather edge boarding and renew with 19mm pressure Impregnated feather edge boarding in areas N.E. 2.00sm including all labours, fixed to existing framework Including renew defective | IT | 51.51 | read |
| 307303 | Carpentry and joinery | Cladding: Remove existing cladding and renew with 19mm pressure impregnated feather edge boarding to match existing in areas over 2.00sm Including all labours, fixed to existing framework Including renew defective suppor | SM | 29.52 | read |
| 307305 | Carpentry and joinery | Cladding : Refix loose timber feather edge boarding to existing framework including renewal of any support battens required and make good decorations | SM | 5.4 | read |
| 307501 | Carpentry and joinery | Cladding : Remove existing defective tongued, grooved and V jointed boarding and renew with 19mm pressure impregnated tongued, grooved and V jointed boarding in areas N.E. 2.00sm including all labours, fixed to existing | IT | 56.99 | read |
| 307503 | Carpentry and joinery | Cladding: Remove existing boarding and renew with 19m tongued, grooved and V jointed pressure impregnated softwood boarding, including all labours, in areas over 2.00sm fixed to existing framework, renew defective suppor | SM | 33.93 | read |
| 307505 | Carpentry and joinery | Cladding : Refix loose timber tongued, grooved and V jointed boarding to existing framework Including renewal of support battens required and make good decorations. | SM | 6.38 | read |
| 307701 | Carpentry and joinery | Cladding : Remove existing defective PVC shiplap cladding and renew with cellular cored PVC shiplap boarding In areas N.E. 2.00sm including all trims, channels and jointing, flXed to existing framework including renew de | IT | 62.16 | read |
| 307703 | Carpentry and joinery | Cladding : Renew any cladding with cellular cored PVC shiplap boarding, in areas over 2.00sm including all trims, channels and jointing, fixed to existing framework including renew defective support battens and provision | SM | 34.6 | read |
| 307705 | Carpentry and joinery | Cladding : Refix loose PVC shlplap cladding to existing framework including renewal of support battens required and all trims, channels and jointing. | SM | 6.38 | read |
| 310101 | Carpentry and joinery | Window : Renew timber window with standard softwood casement window N. E. 1.50sm with softwood clll, Including N.E. 1 No. opening light, factory applied base stain or primer finish, compressible weather-stripping, ironmo | NO | 226.7 | read |
| 310103 | Carpentry and joinery | Window : Renew timber window with standard softwood casement window over 1 50, NE. 3 00sm with softwood cill including N.E. 1 No. opening light, factory applied base stain or primer finish, compressible weather-stripping | NO | 355.76 | read |
| 310105 | Carpentry and joinery | Window . Renew timber window with standard softwood casement window N.E. 1.50sm with softwood c1II, Including N.E. 2 No. opening light, factory applied base stain or primer finish, compressible weather-stripping, ironmon | NO | 288.41 | inferred |
| 310107 | Carpentry and joinery | Window : Renew timber window with standard softwood casement window over 1.50 N.E 3.00sm with softwood cill including N.E, 2 No. opening light, factory applied base stain or pnmer finish, compressible weather-stripping, | NO | 367.34 | inferred |
| 310109 | Carpentry and joinery | Window : Renew timber window with standard softwood casement window over 1.50 N.E. 3.00sm with softwood cill Including N.E. 3 No. opening light, factory applied base stain or primer finish, compressible weather-stripping | NO | 433.18 | read |
| 310111 | Carpentry and joinery | Window : Renew timber window with standard softwood casement window over 3.00sm with softwood clll, including N.E. 3 No. opening light, factory applied base stain or primer finish, compressible weather-stripping, Ironmon | NO | 531.29 | read |
| 310113 | Carpentry and joinery | Window : Renew timber window with standard softwood casement window over 1.50 N.E. 3.00sm with softwood cill including N.E. 4 No. opening light, factory applied stain or primer finish, compressible weather-stripping, iro | NO | 493.27 | read |
| 310115 | Carpentry and joinery | Window : Renew timber window with standard softwood casement window over 3.00sm with softwood cill, including N.E. 4 No. opening light, factory applied base stain or primer finish, compressible weather-stripping, ironmon | NO | 578.59 | read |
| 310301 | Carpentry and joinery | Window : Renew timber window with purpose made softwood casement window N.E. 1.50sm with softwood cill including N.E. 1 No. opening light, apply base stain or primer finish, compressible weather-stripping, ironmongery In | NO | 278.58 | read |
| 310303 | Carpentry and joinery | Window • Renew timber window with purpose made softwood casement window over 1.50, N.E. 3.00sm with softwood clll including N.E. 1 No. opening light, apply base stain or primer finish, compressible weather-stopping, iron | NO | 455.75 | read |
| 310305 | Carpentry and joinery | Window : Renew timber window with purpose made softwood casement window N.E 1.50sm with softwood cill including N.E. 2 No. opening light, apply base stain or pnmer finish, compressible weather-stripping, ironmongery incl | NO | 383.76 | read |
| 310307 | Carpentry and joinery | Window : Renew timber window with purpose made softwood casement window over 1.50, N.E. 3.00sm with softwood cill including N.E. 2 No. opening light, apply base stain or primer finish, compressible weather-stripping, iro | NO | 535.25 | read |
| 310309 | Carpentry and joinery | Window : Renew timber window with purpose made softwood casement window over 1.50, N.E. 3.00sm with softwood cill including N.E. 3 No. opening light, apply base stain or primer finish, compressible weather-stripping, iro | NO | 598.51 | read |
| 310311 | Carpentry and joinery | Window : Renew timber window with purpose made softwood casement window over 3.00sm with softwood cill including N.E. 3 No. opening light, apply base stain or primer finish, compressible weather-stripping, Ironmongery in | NO | 730.22 | read |
| 310313 | Carpentry and joinery | Window ; Renew timber window with purpose made softwood casement window over 1.50, N.E. 3.00sm with softwood clll Including N.E. 4 No. opening light, apply base stain or primer finish, compressible weather-stripping, Iro | NO | 691.12 | read |
| 310501 | Carpentry and joinery | Window • Renew window with purpose made softwood double hung cased box with 2 sashes, overall size N.E 1 S0sm complete with, frame and sashes complete compressible weather-stripping, glazing beads, ironmongery, remove ex | NO | 4.85 | inferred |
| 310503 | Carpentry and joinery | Window : Renew window with purpose made softwood double hung cased box frame and sashes complete with 2 sashes, overall size over 1.50, N E. 3.00sm with, weather-stripping, glazing beads, ironmongery, remove existing and | NO | 661.99 | read |
| 310505 | Carpentry and joinery | Window : Renew window with purpose made softwood double hung cased box frame and sashes complete with 2 sashes, overall size over 3.00sm complete with, glazing beads, ironmongery, remove existing and fix compressible wea | NO | 901.14 | read |
| 310701 | Carpentry and joinery | Window : Renew window with purpose made softwood horizontal pivot hung window complete with, compressible weather-stripping, complete, overall size N.E. 1.75sm glazing beads, ironmongery, fix frame to prepared opening, b | NO | 4.07 | inferred |
| 311101 | Carpentry and joinery | window with standard hardwood casement window N.E. Window : Renew timber 1 50sm with hardwood cill, including N E. 1 No opening light, factory applied base handles, stain finish, compressible weather-stripping, ironmonge | NO | 3.19 | inferred |
| 311103 | Carpentry and joinery | window over Window : Renew timber window with standard hardwood casement 1.50, N.E 3.00sm with hardwood cill including N E. 1 No. opening light, factory applied base stain, compressible weather-stripping, ironmongery inc | NO | 479.28 | read |
| 311105 | Carpentry and joinery | Window : Renew timber window with standard hardwood casement window N.E. 1.50sm with hardwood cill, including N.E. 2 No. opening light, factory applied base including locking handles, stain finish, compressible weather-s | NO | 413.69 | read |
| 311107 | Carpentry and joinery | Window : Renew timber window with standard hardwood casement window over 3 with hardwood cill including N.E No. opening light, factory 1.50, N.E. OOsm 2 applied base stain, compressible weather-stripping, ironmongery inc | NO | 577.09 | read |
| 311109 | Carpentry and joinery | Renew timber window wrth standard hardwood casement window over Window : 1.50, N.E. 3.00sm with hardwood cill including N E. 3 No. opening light, factory applied base stain, compressible weather-stripping, ironmongery in | NO | 639.22 | read |
| 311111 | Carpentry and joinery | Window : Renew timber window with standard hardwood casement window over 3.00sm with hardwood clll, including N.E. 3 No. opening light, factory applied stain finish, compressible weather-stripping, Ironmongery Including | NO | 749.47 | inferred |
| 311113 | Carpentry and joinery | Window : Renew timber window with standard hardwood casement window over 1.50, N.E. 3.00sm with hardwood cill Including N.E. 4 No. opening light, factory applied base stain, compressible weather-stripping, ironmongery In | NO | 713.8 | read |
| 311115 | Carpentry and joinery | Window : Renew timber window with standard hardwood casement window over 3.00sm with hardwood cill, Including N.E 4 No. opening light, factory applied base stain finish, compressible weather-stripping, Ironmongery Includ | NO | 809.59 | read |
| 311301 | Carpentry and joinery | Window • Renew timber window with purpose made hardwood casement window N.E. 1.50sm with hardwood cill Including N.E. 1 No. opening light, apply base stain, compressible weather-stripping, ironmongery including locking h | NO | 430.61 | read |
| 311303 | Carpentry and joinery | Window : Renew timber window with purpose made hardwood casement window over 1.50, N.E. 3.00sm with hardwood cill including N.E. 1 No. opening light, apply stain, compressible weather-stripping, Ironmongery including loc | NO | 676.49 | read |
| 311305 | Carpentry and joinery | Window : Renew timber window with purpose made hardwood casement window N.E. 1.50sm with hardwood cill Including N.E. 2 No. opening light, apply base stain, compressible weather-stripping, ironmongery including locking h | NO | 620.02 | read |
| 311307 | Carpentry and joinery | Window : Renew timber window with purpose made hardwood casement window over 1.50, N.E. 3.00sm with hardwood cill including N E. 2 No. opening light, apply stain, compressible weather-stripping, ironmongery including loc | NO | 802.85 | read |
| 311309 | Carpentry and joinery | Window : Renew timber window with purpose made hardwood casement window over 1.50, N.E. 3.00sm with hardwood cill including N.E. 3 No. opening light, apply stain, compressible weather-stripping, ironmongery including loc | NO | 944.61 | read |
| 311311 | Carpentry and joinery | Window : Renew timber window with purpose made hardwood casement window over 3.00sm with hardwood cill including N.E. 3 No. opening light, apply base stain, compressible weather-stripping, ironmongery Including locking h | NO | 1119.24 | read |
| 311313 | Carpentry and joinery | Window : Renew timber window with purpose made hardwood casement window over 1 50, N.E. 3.00sm with hardwood cill Including N.E. 4 No. opening light, apply stain, compressible weather-stripping, Ironmongery including loc | NO | 1117.03 | read |
| 311315 | Carpentry and joinery | Window : Renew timber window with purpose made hardwood casement window over 3 OOsm with hardwood clll lncludlng N.E. 4 No. opening light, apply stain, Including locking handles, glazing compressible weather-stripping, I | NO | 1208.68 | read |
| 311501 | Carpentry and joinery | Window : Renew window with purpose made hardwood double hung cased box frame and sashes complete with 2 sashes, overall size N.E. 1.50sm complete with compressible weather-stripping, glazing beads, ironmongery, remove ex | NO | 793.96 | read |
| 311503 | Carpentry and joinery | Window : Renew window with purpose made hardwood double hung cased box and sashes complete with 2 sashes, overall size over 1.50, N.E. 3.00sm frame complete with compressible weather-stripping, glazing beads, ironmongery | NO | 1056.1 | read |
| 311505 | Carpentry and joinery | Window : Renew window with purpose made hardwood double hung cased box frame and sashes complete with 2 sashes, overall size over 3.00sm complete with compressible weather-stripping, glazing beads, ironmongery, remove ex | NO | 1429.59 | read |
| 311701 | Carpentry and joinery | hardwood horizontal pivot hung Window : Renew window with purpose made window complete, overall size N.E. 1.75sm complete with compressible weather- stnpping, glazing beads, ironmongery, fix frame to prepared opening, be | NO | 631.73 | read |
| 312001 | Carpentry and joinery | Window : Renew timber window with standard softwood feature window N.E. 5.00sm overall with combination of fixed and opening hghts and panels, factory applied base stain or primer finish, compressible weather-stripping, | NO | 631.5 | read |
| 313001 | Carpentry and joinery | Window : Renew timber window with standard hardwood feature window N. E. 5.00sm overall with combination of fixed and opening lights and panels, factory applied base stain finish, compressible weather-stripping, ironmong | NO | 888.19 | read |
| 313501 | Carpentry and joinery | window with purpose made PVCu factory glazed Window : Renew any type horizontal pivot hung window complete with cill, double glazed internally with 20mm thick hermetically sealed units, overall size N.E. 1.75sm complete | NO | 4.0 | inferred |
| 313601 | Carpentry and joinery | factory glazea Window : Renew any type window with purpose made PVCu window N.E. 1.50sm with cill, double glazed Internally with 20mm thick casement hermetically sealed units, including N.E. 1 No. opening light, thermal | NO | 257.98 | read |
| 313603 | Carpentry and joinery | Window : Renew any type window with purpose made PVCu factory glazed casement window over 1.50, N.E. 3.00sm with clll, double glazed internally with 20mm thick hermetically sealed units, Including N.E. 1 No. opening ligh | NO | 3.42 | inferred |
| 313605 | Carpentry and joinery | Window : Renew any window type with purpose made PVCu factory glazed casement window N.E. 1.50sm with cill, double glazed Internally with 20mm thick hermetically sealed units, including N.E. 2 No. opening light, thermal | NO | 368.73 | read |
| 313607 | Carpentry and joinery | Window : Renew any type window with purpose made PVCu factory glazed casement window over 1.50, N.E. 3.00sm with cill, double glazed Internally with 20mm thick hermetically sealed units, Including N.E. 2 No opening light | NO | 513.58 | read |
| 313611 | Carpentry and joinery | Window : Renew any type window with purpose made PVCu factory glazed casement window over 3 00sm with clll, double glazed Internally with 20mm thick hermetically sealed units, including N.E. 3 No. opening lights, thermal | NO | 676.77 | read |
| 313613 | Carpentry and joinery | Window : Renew any type window with purpose made PVCu factory glazed casement window over 1.50, N.E. 3.00sm with clll, double glazed internally with 20mm thick hermetically sealed units, Including N.E. 4 No. opening figh | NO | 681.15 | read |
| 313615 | Carpentry and joinery | Window • Renew any type window with purpose made PVCu factory glazed casement window over 3.00sm with clll, double glazed internally with 20mm thick hermetically sealed units, including N.E. 4 No. opening lights, thermal | NO | 718.57 | read |
| 313701 | Carpentry and joinery | Window : Renew any type window with purpose made PVCu factory glazed tilt/tum window N.E. 1.50sm with cill, double glazed Internally with 20mm thick hermetically sealed units, including N.E. 1 No. opening light, thermal | NO | 276.42 | read |
| 313703 | Carpentry and joinery | Window : Renew any type window with purpose made PVCu factory glazed tllUtum window over 1.50, N.E. 3.00sm with cill, double glazed Internally with 20mm thick hermetically sealed units, including N.E. 1 No. opening light | NO | 413.77 | read |
| 313705 | Carpentry and joinery | Window : Renew any type window with purpose made PVCu factory glazed tilt/tum window N.E. 1.50sm with cill, double glazed Internally with 20mm thick hermetically sealed units, including N.E. 2 No. opening lights, thermal | NO | 412.35 | read |
| 313707 | Carpentry and joinery | Window : Renew any type window with purpose made PVCu factory glazed tilt/tum window over 1.50, N.E. 3.00am with cill, double glazed internally with 20mm thick hermetically sealed units, including N.E 2 No. opening light | NO | 509.84 | inferred |
| 313709 | Carpentry and joinery | Window : Renew any type window with purpose made PVCu factory glazed tilt/tum window over 1.50, N.E. 3 0Osm with cill, double glazed internally with 20mm thick hermetically sealed units, including N E. 3 No. opening ligh | NO | 619.62 | read |
| 313711 | Carpentry and joinery | Window : Renew any type window with purpose made PVCu factory glazed tilt/tum window over 3.00sm with cill, double glazed internally with 20mm thick hermetically sealed units, including N.E. 1 No. opening light, thermal | NO | 716.18 | read |
| 313713 | Carpentry and joinery | Window • Renew any type window with purpose made PVCu factory glazed tilt/tum window over 1.50, N.E 3.00sm with cill, double glazed internally with 20mm thick hermetically sealed units, including N.E. 4 No opening lights | NO | 740.96 | read |
| 315001 | Carpentry and joinery | Window : Ease any size and type of opening sash, pivot sash, sliding sash including remove and refix sash. beads etc, oll and adjust hinges and Ironmongery as necessary, touch up decoration to match existing, test to ens | NO | 8.03 | read |
| 315009 | Carpentry and joinery | Sash: Renew N.E. 900x600mm fixed sash with preservative treated softwood sash, consisting of any size or profile members to match existing and bedded in linseed oil putty and screw fixed to frame, single glazed and decor | NO | 62.12 | read |
| 315011 | Carpentry and joinery | Window : Renew N.E. 1. 75sm pivot sash with preservative treated softwood pivot, consisting of any size or profile to match existing framing and hanging on new pair of pivot hinges, single glazed and decorate to match ex | NO | 143.16 | read |
| 315013 | Carpentry and joinery | Window : Renew preservative treated softwood sliding sash to box sash window, any size or profile to match existing, complete with cords, ease and adjust, single glazed and decorate to match existing | NO | 135.39 | read |
| 315015 | Carpentry and joinery | Window : Renew sonwood parting bead to box sash window complete and decorate to match existing. | LM | 6.61 | read |
| 315017 | Carpentry and joinery | Window : Renew softwood staff bead to box sash window complete and decorate to match existing. | LM | 4.56 | read |
| 315019 | Carpentry and joinery | Window : Renew set of pulley cords complete including remove and refix sliding sash pockets and beads and ease pulley (per sash). | IT | 14.22 | read |
| 315021 | Carpentry and joinery | Window : Renew sliding sash pulley wheel Including remove and refix sash and renew cords If required, touch up decorations to match existing. | NO | 19.35 | read |
| 315023 | Carpentry and joinery | Box Sash : Renew weight(s) to sliding sash including remove and refix sash and renew cords if required, touch up decorations to match existing. | NO | 27.91 | read |
| 315025 | Carpentry and joinery | Balance • Renew any type and size of spiral balances to double hung sash unit including remove/refix sashes, beads, linings etc, renew balances, test and make good decorations to match existing. | IT | 75.69 | read |
| 315027 | Carpentry and joinery | Frame : Cut out and splice in new section treated softwood frame any size or profile to match existing, plugged to brick work and pointed with sealant, make good to plasterwork and decorate to match existing. | LM | 31.02 | read |
| 315029 | Carpentry and joinery | Cill : Cut out and splice in new section N.E. 300mm long any size or profile of preservative hardwood cill to match existing frame, plugged to brickwork, and pointed with sealant, make good plasterwork and decorate to ma | IT | 24.09 | read |
| 315031 | Carpentry and joinery | Cill • Cut out and splice In new section over 300mm long any size or profile of preservative hardwood clll to match existing frame, plugged to brickwork, and pointed with sealant. make good plasterwork and decorate to ma | LM | 34.94 | read |
| 315035 | Carpentry and joinery | Window: Renew with 14x20mm preservative treated softwood or hardwood glazing bead and decorate to match existing. | LM | 4.89 | inferred |
| 315039 | Carpentry and joinery | Window : Refix loose glazing bead and bed In sealant | LM | 3.98 | read |
| 315041 | Carpentry and joinery | Window : Renew front section of cill with any size or profile to match existing with screws and pellated and bed in sealant including cut out defective section and shape new to match existing, redecorate to match existin | LM | 12.88 | read |
| 315043 | Carpentry and joinery | Window : Renew glazing bar, any size or profile to match existing, reglaze with existing glass, splice new section, remove/refix sashes as required, redecorate to match existing (refixing of glass is Contractors risk). | LM | 30.13 | read |
| 315045 | Carpentry and joinery | Window . Renew weather or parrot mould, cut out old and fix new mould, redecorate to match existing. | LM | 4.77 | read |
| 315051 | Carpentry and joinery | Window : Overhaul timber sash window, renew staff and parting beads, take out sashes and later rehang on appropriate sized new undyed plaited nylon sash cords, renew pocket pieces, wedge and cramp loose sash frames, oil | NO | 30.58 | read |
| 316401 | Carpentry and joinery | Window : Ease and oil butts to metal window including force open if necessary, strip paint, file and grind edges. | NO | 3.99 | read |
| 316405 | Carpentry and joinery | Window : Renew proprietary weather/draught proofing to any opening light to metal window and adjust Window as necessary to ensure effective operation. | IT | 16.23 | read |
| 316407 | Carpentry and joinery | Window : Overhaul any type of metal window, dismantle as necessary and subsequently reassemble Including freeing, easing, oiling and adjusting casements to give correct operation, Including file and grind edges, renew fi | NO | 24.25 | read |
| 317201 | Carpentry and joinery | Window : Ease and oll butts to any type of aluminium window including renewing runners if necessary. | NO | 5.1 | read |
| 317205 | Carpentry and joinery | Window . Overhaul any type of aluminium window, dismantle as necessary and subsequently reassemble including freeing, easing and adjusting casements to give correct operation, renew fixing screws, remove, refit or renew | NO | 24.25 | read |
| 318101 | Carpentry and joinery | Window : Renew any size and type of fanlight sash to PVCu window including double glazing and all Ironmongery and make good. | NO | 47.48 | read |
| 318103 | Carpentry and joinery | Window : Renew any size and type of sideling sash to PVCu window Including double glazing and all ironmongery and make good. | NO | 87.43 | inferred |
| 318105 | Carpentry and joinery | Window : Renew or repair any trickle vent to PVCu window. | IT | 9.05 | read |
| 318107 | Carpentry and joinery | Window : Renew any defective or broken handle to PVCu window including remove existing, check, lubricate operating mechanism, renew handle to match existing and test | NO | 11.96 | read |
| 318108 | Carpentry and joinery | Window : Renew any defective or broken locking handle to PVCu window including remove existing, check, lubricate operating mechanism, renew handle to match existing and test. | NO | 16.01 | read |
| 318109 | Carpentry and joinery | Window : Renew any defective or broken hinge to PVCu window including remove existing and renew hinge to match existing. | NO | 6.98 | read |
| 318111 | Carpentry and joinery | Window : Renew any defective or broken espagnolette locking mechanism to PVCu window Including remove existing and renew to match existing and test. | IT | 15.2 | read |
| 318113 | Carpentry and joinery | Window : Renew sealing gasket to any opening light of PVCu window (per opening light). | IT | 4.51 | read |
| 318115 | Carpentry and joinery | Window : Check operation of all fittings and operating mechanisms to PVCu window complete including lubricate and adjust as necessary | IT | 3.99 | read |
| 318117 | Carpentry and joinery | Window • Ease and adjust PVCu sash including realign as necessary | IT | 6.62 | inferred |
| 318119 | Carpentry and joinery | Window : Check operation of tilt and tum mechanism to PVCu window including overhaul, lubricate and adjust as necessary | NO | 11.12 | read |
| 318121 | Carpentry and joinery | Window : Renew any tilt and tum mechanism complete to PVCu window of any size to match existing, Including remove existing, test and leave In proper working order. | NO | 90.09 | read |
| 318123 | Carpentry and joinery | Window : Renew or supply and fix new adjustable child proof restrictor/catch to any type of PVCu window including removing existing fitting. | NO | 7.81 | read |
| 318125 | Carpentry and joinery | Window : Overhaul any type of PVCu window, dismantle as necessary and subsequently reassemble including freeing, easing and adjusting casements to give correct operation, renew fixing screws, remove, refrt or renew ironm | NO | 24.25 | read |
| 318151 | Carpentry and joinery | Window : Renew any type of defective PVcu glazlng bead Including remove existing bead, clean, prepare and supply and fit new bead to match existing including all cutting, mitres, sealing with silicone sealant as necessar | LM | 4.19 | read |
| 318155 | Carpentry and joinery | Window : Renew gasket to any style of PVCu window opening light | LM | 1.61 | inferred |
| 318157 | Carpentry and joinery | Window : Renew any type of stay with stainless steel friction stay to PVCu window. | NO | 5.73 | inferred |
| 318159 | Carpentry and joinery | Window : Renew plastic restraining wedges to friction stay guide to PVCu window. | NO | 2.08 | read |
| 318161 | Carpentry and joinery | Window : Renew restrictor stay to match existing to PVCu window. | NO | 7.81 | read |
| 318163 | Carpentry and joinery | Window : Renew any type of window handle and striker plate with 'Securistyle Empress' locking plate to PVCu window. | NO | 11.05 | read |
| 318165 | Carpentry and joinery | Window: Renew drip mould bead to PVCu window and make good. | LM | 3.54 | read |
| 318167 | Carpentry and joinery | Window : Provide standard section PVCu drip mould bead, fix to PVCu window and make good. | LM | 2.77 | read |
| 318169 | Carpentry and joinery | I Window: Provide 30mm standard section PVCu extension flange, fix to t-'Vl;U window and make good. | LM | 4.06 | read |
| 318171 | Carpentry and joinery | Window : Provide standard section PVCu extension flange, fix to PVCu ◄Smm window and make good | LM | 4.32 | read |
| 318179 | Carpentry and joinery | Window : Rake out, prepare and repoint with silicone mastic sealant complete around any external face of PVCu window frame. | LM | 2.51 | read |
| 318181 | Carpentry and joinery | Window • Renew cellular PVCu quadrant cover fillet fixed with approved adhesive or other approved concealed fixing method Internally around windows make good plasterwork and decorations. | LM | 3.54 | read |
| 318185 | Carpentry and joinery | Window : Renew standard section PVCu cill to PVCu window, remove existing cill, clean, prepare and supply and fit new cill to match existing including end caps, all cutting, mitres, sealing with silicone sealant as neces | LM | 12.42 | read |
| 318187 | Carpentry and joinery | Window : Provide standard section PVCu cill to PVCu window clean, prepare and supply and fit new cill including end caps all cutting, mitres, sealing with silicone sealant as necessary and make good. | LM | 9.85 | inferred |
| 318189 | Carpentry and joinery | Window : Renew any missing or broken ctll ends to PVCu window (per window). | NO | 1.42 | read |
| 318201 | Carpentry and joinery | Door Frame : Rake out, prepare and repoint with silicone mastic sealant complete around any door frame of any size (per face). | IT | 9.57 | read |
| 318203 | Carpentry and joinery | Window Frame : Rake out, prepare and repoint with silicone mastic sealant complete around any window frame (per face). | IT | 10.42 | read |
| 318207 | Carpentry and joinery | Window Frame ; Provide and fix suitable size PVCu quadrant or flexible PVC cover trim fixed with silicone mastic sealant to form a neat clean beaded surround, to jambs and head of any window frame, any location Internall | NO | 15.92 | read |
| 319001 | Carpentry and joinery | Roof Window: Renew roof window complete size N.E. 0.78x0.98m with Velum aluminium clad externally roof window with factory fitted clear float double glazed sealed unit, all upstands, flashings and dressing of flashings, | NO | 328.22 | read |
| 319003 | Carpentry and joinery | Roof Window : Renew roof window complete size N. E. 1.14x1 .18m with Velum aluminium clad externally roof window with factory fitted clear float double glazed sealed unit, all upstands, flashings and dressing of flashing | NO | 406.51 | read |
| 319005 | Carpentry and joinery | Roof Window : Renew roof window complete size N E. 1.34x1 .40m with Velum aluminium clad externally roof window with factory fitted clear float double glazed sealed unit, all upstands, flashings and dressing of flashings | NO | 475.19 | read |
| 319101 | Carpentry and joinery | Roof Window : Redress roof flashings around roof window and reseal to prevent water penetration. | NO | 13.38 | read |
| 319103 | Carpentry and joinery | Roof Window : Overhaul opening gear to any type of roof window. | NO | 17.3 | read |
| 319105 | Carpentry and joinery | Roof Window : Renew operating control cords to any roof window. | NO | 19.58 | read |
| 319107 | Carpentry and joinery | Roof Window : Redress roof flashings around roof window and reseal to prevent water penetration. | NO | 12.2 | read |
| 321105 | Carpentry and joinery | Door : Renew back door with any size 44mm hardwood panelled, glazed or part glazed door prepared for glazing, hang on 1.5 pair butts, fix new mortice lock, furniture, keep, pair of bolts, hardwood weathermould, adjust st | NO | 380.48 | read |
| 321107 | Carpentry and joinery | Door : Renew front door with any size 44mm hardwood panelled, glazed or part glazed door prepared for glazing, hang on 1.5 pair butts, fix new mortice lock, furniture, keep, pair of bolts, cylinder latch and pull, securi | NO | 479.01 | read |
| 321305 | Carpentry and joinery | Door : Renew back door with any size 44mm hardwood panelled, glazed or part glazed purpose made door prepared for glazing, hang on 1.5 pair butts, frx new mortice lock, furniture, keep, pair of bolts, hardwood weathermou | NO | 4.93 | inferred |
| 321307 | Carpentry and joinery | Door : Renew front door With any stze 44mm hardwood panelled, glazed or part glazed purpose made door prepared for glazing, hang on 1.5 pair butts, fl)( new mortice lock, furniture, keep, pair of bolts, cylinder latch an | NO | 591.53 | read |
| 321505 | Carpentry and joinery | Door : Renew back door with any size 44mm softwood panelled, glazed or part glazed door prepared for glazing, hang on 1.5 pair butta, fix new mortice lock, furniture, keep, pair of bolts, softwood weathermould, adjust st | NO | 336.18 | read |
| 321507 | Carpentry and joinery | Door : Renew front door with any size 44mm softwood panelled, glazed or part glazed door prepared for glazing, hang on 1.5 pair butts, fix new mortice lock, furniture, keep, pair of bolts, cylinder latch and pull, securi | NO | 432.13 | read |
| 321705 | Carpentry and joinery | Door : Renew back door with any size 44mm softwood panelled. glazed or part glazed purpose made door prepared for glazing, hang on 1.5 pair butts, fix new mortice lock, furniture, keep, pair of bolts, softwood weathermou | NO | 434.22 | inferred |
| 321707 | Carpentry and joinery | Door : Renew front door with any size 44mm softwood panelled, glazed or part glazed purpose made d09r prepared for glazing, hang on 1.5 pair butts, fix new mortice lock, furniture, keep, pair of bolts, cylinder latch and | NO | 527.6 | read |
| 322101 | Carpentry and joinery | Door . Renew back door with any size proprietary high performance door or similar prefinlshed and preglazed, hang on 1.5 pair butts, fix new mortice lock, door furniture, keeps, pair of bolts, proprietary weathermould, a | NO | 419.17 | read |
| 322103 | Carpentry and joinery | Door : Renew front door with any size proprietary high performance door or similar prefinished and preglazed, hang on 1.5 pair butts, fix new mortice lock, door furniture, keeps, pair of bolts, cylinder nightlatch and pu | NO | 504.57 | inferred |
| 323101 | Carpentry and joinery | Door : Renew front door with any size 0.50hr flush firecheck door and hang on pair butts, fix new mortice lock, furniture and keep, pair bolts, cylinder latch and pull, security restraint device letter plate including cu | NO | 357.55 | read |
| 323103 | Carpentry and joinery | Door . Renew front door with any size 1.00hr flush firecheck door and hang on pair butts, fix new mortice lock, furniture and keep, pair bolts, cylinder latch and pull, security restraint device letter plate including cu | NO | 489.96 | read |
| 323105 | Carpentry and joinery | Door : Renew communal door with any size 0.50hr flush firecheck door and hang on 1.5 pair butts, fix new mortice dead lock, furniture and keep, door closer, including cutting/adapting mortice in door to suit, fix new wea | NO | 244.41 | read |
| 323107 | Carpentry and joinery | Door: Renew communal doorwIth any size 1.00hr flush firecheck door and hang on 1.5 pair butts, fix new firecheck door and hang on 1. 5 pair butts, fix new mortice dead lock, furniture and keep, door closer, Including cut | NO | 359.22 | inferred |
| 323501 | Carpentry and joinery | Door : Renew any type door and frame with any size PVCu panelled/ half glazed door, double glazed internally with 20mm thick hermetically sealed unit, PVCu frame, prehung, complete with mult1polnt locking system, handles | NO | 529.58 | read |
| 323503 | Carpentry and joinery | Door : Renew any type door and frame with any size PVCu two paneVhalf glazed door, double glazed internally with 20mm thick hermetically sealed unit, PVCu frame, prehung, complete with multipoint locking system, handles, | NO | 601.66 | read |
| 323505 | Carpentry and joinery | Door : Renew any door with any size PVCu panelled/half glazed door, double glazed internally with 20mm thick hermetically sealed unit hanging to existing PVCu frame on new hinges, complete with multipoint locking system, | NO | 411.3 | read |
| 323507 | Carpentry and joinery | Door : Renew any door with any size PVCu two paneVhalf glazed door, double glazed Internally with 20mm thick hermetically sealed unit hanging to existing PVCu frame on new hinges, complete with multipoint locking system, | NO | 411.3 | read |
| 323509 | Carpentry and joinery | DOOR: Renew any type door and frame with pair of any size N.E. 5.00sm PVCu French tilt/tum door, double glazed internally 20mm thick, hermetically sealed unit, PVCu frame, prehung, complete with multipoint locking system | IT | 1242.37 | read |
| 323601 | Carpentry and joinery | Door : Renew back door with any size panelled, glazed or partially glazed or similar proprietary high performance PVCu door, prefinished and preglazed, hang on pair butts, fix new mortice lock, door furniture, keeps, pai | NO | 529.58 | read |
| 323603 | Carpentry and joinery | Door : Renew front door with any size panelled, glazed or partially glazed or similar proprietary high performance PVCu door, prefinished and preglazed, hang on pair butts, fix new mortice lock, door furniture, keeps, pa | NO | 608.99 | read |
| 324101 | Carpentry and joinery | Door : Ease and adjust door, hung on up to 1.5 pairs of butt hinges, Including remove and rehang door as necessary and make good to butt recesses to frame and touch up decorations. | NO | 8.1 | read |
| 324107 | Carpentry and joinery | Door : Refix loose glazing beads to door including bedding and sealing with sealant (per door). | NO | 4.98 | read |
| 324109 | Carpentry and joinery | Door: Renew 9mm external quality plywood panel size 610x610mm to door, including remove weatherseal, refix or renew beads, renew weatherseal and decorate to match existing. | NO | 18.45 | read |
| 324111 | Carpentry and joinery | Door : Patch, repair hanging or closing stile of softwood door including cut out and splice in new timber up to 600mm long, and decorate to match existing. | NO | 17.76 | read |
| 324113 | Carpentry and joinery | Door : Renew closing stile to softwood door, remove glass or plywood panels and beads and set aside, take down door and remove hinges, remove ironmongery and set aside, cut out defective stile to top, and bottom rails, r | IT | 42.92 | read |
| 324115 | Carpentry and joinery | Door : Supply and fix preservative treated redwood weatherboard to door, bedded and pointed in sealant, cut out base of door frame to accommodate weatherboard and decorate to match existing. | NO | 9.28 | read |
| 324117 | Carpentry and joinery | Door : Supply and fix 50x19mm hardwood bevelled rain deflector with neoprene or rubber flexible pad at bottom, bedded in sealant and screwed to face of door. | NO | 9.01 | read |
| 324119 | Carpentry and joinery | Door : Renew with preservative treated hardwood rebated splayed and twice rounded glazing beads of any size and of any profile including mitres and ends to door, bedding/pointing with sealant and decorate to match existi | LM | 5.92 | read |
| 324121 | Carpentry and joinery | Door • Renew closing stile to hardwood door, remove glass or plywood panels and beads and set aside, take down door and remove hinges, remove ironmongery and set aside, cut out defective stile to top, middle and bottom r | IT | 59.05 | read |
| 324123 | Carpentry and joinery | Door . Overhaul external door and frame complete, remove all ironmongery, piece out door, frame and architraves where ironmongery removed make good any damage, defects to timber, resecure architraves if loose, rehang doo | NO | 53.75 | read |
| 324125 | Carpentry and joinery | Door : Overhaul external door and frame with fanlight complete, remove all ironmongery, piece out door, frame, and architraves where ironmongery removed make good any damage, defects to timber, resecure glazing beads, an | NO | 70.05 | read |
| 324127 | Carpentry and joinery | Door : Overhaul external part glazed/panelled door and frame complete, remove all ironmongery, piece out door, frame and architraves where ironmongery removed make good any damage, defects to timber, resecure architraves | NO | 104.6 | read |
| 324129 | Carpentry and joinery | Door : Overhaul external half glazed/panelled door and frame complete, remove all ironmongery, piece out door, frame and architraves where ironmongery removed make good any damage, defects to timber, resecure architraves | NO | 149.97 | read |
| 325101 | Carpentry and joinery | Door . Renew any butt hinge to PVCu door. | NO | 8.74 | read |
| 325103 | Carpentry and joinery | Door : Overhaul and lubricate multipoint locking system to PVCu door. | IT | 6.75 | read |
| 325105 | Carpentry and joinery | Door : Renew any defective or broken multipoint door locking system complete to PVCu door, adapt keep if necessary, including remove existing, test and leave in working proper working order. | NO | 74.64 | read |
| 325107 | Carpentry and joinery | Door . Carefully remove existing PVCu door lock, ease and adjust door in order to ensure correct working, refix existing lock. | NO | 15.51 | read |
| 325109 | Carpentry and joinery | Door : Renew any type of lock cylinder to PVCu door including drilling out old cylinder, replacing With new matching cylinder complete with 2 No. keys, make good, test and leave In proper working order. | NO | 22.01 | read |
| 325111 | Carpentry and joinery | Door : Henew any door catch or keep to PVCu door including all adjustment and making good necessary. | NO | 8.62 | read |
| 325113 | Carpentry and joinery | Door : Repair any type of door handle to PVCu door including carefully removing and refixlng as necessary and making good. | NO | 8.96 | read |
| 325115 | Carpentry and joinery | Door : Carefully remove existing pair of lever handles and plates and remove from site, provide and fix new set of lever handles and plates to PVCu door (per set). | NO | 50.05 | read |
| 325117 | Carpentry and joinery | Door ; Overhaul any PVCu or glazed PVCu door, Including remove door from trame, ease and adjust foot of door, adjust door locking mechanisms and hinges to ensure that door operates correctly, rehang door to existing fram | NO | 30.26 | read |
| 325123 | Carpentry and joinery | Door : Supply and fix composite Insulated panel PVCu faced both sides to PVCu door, fixed with and Including matching PVCu trim and beading, carefully remove existing defective and redundant panel or glazing and making g | NO | 66.51 | read |
| 325125 | Carpentry and joinery | Door : Supply and fix composite insulated panel PVCu faced both sides to PVCu door, fixed with and including matching PVCu trim and beading. carefully remove existing defective and redundant panel or glazing and making g | NO | 98.64 | inferred |
| 326105 | Carpentry and joinery | Door . Ease Including force open if necessary, strip paint, file and grind edges, ease and oil hinges to steel door. | NO | 7.85 | read |
| 326107 | Carpentry and joinery | Door : Renew lock to any Crittall type of steel door Including remove existing and fix new, make all necessary adjustments to door frame, make good decorations and provide 2 No. keys. | NO | 50.81 | read |
| 327101 | Carpentry and joinery | Door : Ease including force open if necessary, strip paint, file and grind edges, ease and oll hinges to aluminium door. | NO | 5.27 | read |
| 327103 | Carpentry and joinery | Door : Renew lock to any type of aluminium door Including remove existing and fix new, make all necessary adjustments to door and frame, make good decorations and provide 2 No. keys. | NO | 50.81 | read |
| 327105 | Carpentry and joinery | Door : Renew any glazed doors and frame, with polyester powder coated aluminium external glazed patio doors and frame, Including double glazing internally with 20mm thick hermetically sealed safety glass unit, frame buil | NO | 1157.5 | read |
| 328101 | Carpentry and joinery | Door : Renew external door with any size 40mm thick single softwood matchboard ledged and braced door with 169x20mm ledges and 106x20mm braces covered on face with 20mm tongued, grooved and v jointed boarding, including | NO | 164.41 | read |
| 328103 | Carpentry and joinery | Door : Renew external door with any size 40mm thick single softwood matchboard framed, ledged and braced door with 169x20mm ledges and 106x20mm braces covered on face with 20mm tongued, grooved and v jointed boarding, in | NO | 182.51 | read |
| 328105 | Carpentry and joinery | Door· Renew 114x25mm preservative treated softwood tongued and grooved board to ledged and braced door and decorate to match existing. | IT | 14.08 | read |
| 328107 | Carpentry and joinery | Door. Renew 105x20mm preservative treated softwood ledge or brace to ledged and braced door, and decorate to match existing. | IT | 7.54 | read |
| 328109 | Carpentry and joinery | Frame : Renew external garage door frame with any size or profile of treated softwood door frame to suit any size single door, remove existing door and set aside, take out existing frame and bed new frame in cement morta | NO | 163.96 | read |
| 328111 | Carpentry and joinery | Frame : Renew fillet any size or profile to garage door frame Including remove existing and decorate to match existing. | LM | 6.68 | read |
| 330001 | Carpentry and joinery | Door: Renew internal door with any size N.E 40mm thick single skeleton core flush door with 3.2mm luan. white Merantl or other approved plywood facing both sides and 9mm hardwood lipping on long edges, including remove e | NO | 110.69 | read |
| 330003 | Carpentry and joinery | Door: Renew internal door with any size N.E. 40mm thick single skeleton core hardboard faced both sides flush internal door with hardwood tipping on long edges including remove existing door and hinges, remove and refrt | NO | 102.05 | read |
| 330005 | Carpentry and joinery | Door : Renew intemal door with any size N.E. 40mm thick single embossed hardboard panelled door including remove existing door and hinges. remove and refit door stops as necessary, fit and hang new door on one pair of 10 | NO | 116.11 | read |
| 330007 | Carpentry and joinery | Door: Renew internal door with any size N.E. 40mm thick framed softwood glazed door including remove existing door and hinges, remove and refix door stops as necessary, frt and hang new door on 1.5 pair of 100mm steel bu | NO | 211.19 | read |
| 330009 | Carpentry and joinery | Door : Renew Internal door with any size N E. 40mm thick framed hardwood glazed door Including remove existing door and hinges, remove and refit door stops as necessary, fit and hang new door on 1.5 pairs of 100mm steel | NO | 260.6 | read |
| 330011 | Carpentry and joinery | Door: Renew Internal door with any size N.E. 40mm thick hardwood veneered door Including remove existing door and hinges, remove and refit door stops as necessary, fit and hang new door on one pair of 100mm steel butt hi | NO | 94.86 | read |
| 330013 | Carpentry and joinery | Door : Renew Internal door with any size single half-hour fire check flush door having 3.2mm luan, white Meranti or other approved plywood facing both sides and 9mm hardwood lipping on long including remove existing door | NO | 172.47 | read |
| 330015 | Carpentry and joinery | Door : Renew internal door with any size single one-hour fire check flush door having 3.2mm luan, white Meranti or other approved plywood facing both sides and 9mm hardwood lipping on long edges, including remove existin | NO | 279.95 | read |
| 330017 | Carpentry and joinery | Door : Renew internal door with any size single half-hour fire check glazed door having 3 2mm luan, white Meranti or other approved plywood facing both sides and 9mm hardwood lipping on long edges, Including remove exist | NO | 189.1 | read |
| 330019 | Carpentry and joinery | Door : Supply and fix sliding door gear for hanging of any Internal door. | NO | 45.27 | read |
| 330021 | Carpentry and joinery | Door : Cut opening in solid or hollow core door for 225x75mm aluminium louvre ventilators and screw fix new ventilators to both faces of door. | IT | 7.89 | read |
| 330023 | Carpentry and joinery | Door : Cut opening approx. 500x500mm In flush door and form vision panel, glazed In laminated safety glass, bedded In washleather strip with minimum 15mm chamfered beads fixed with brass cups and screws and decorate. | NO | 43.7 | read |
| 335003 | Carpentry and joinery | Door . Ease, reduce if required and adjust internal door including take off and rehang on new butts, adjust stops or ease rebates, make good to door and lining as necessary and touch up paintwork to match existing | NO | 18.28 | read |
| 335005 | Carpentry and joinery | Door : Patch in and make good as necessary patch in softwood door, touch up decorations to match existing. | IT | 26.88 | read |
| 335007 | Carpentry and joinery | Door : Patch in and make good as necessary patch in hardwood door, touch up decorations to match existing. | IT | 28.02 | read |
| 335009 | Carpentry and joinery | Door . Renew any rail or stile to any type of softwood door Including remove and rehang door, remove and refix hinges, locks, furniture and the llke In order to effect repairs and decorate to match existing. | IT | 35.2 | read |
| 335011 | Carpentry and joinery | Door : Renew hardwood edging stnps to any door glued and pinned to existing door Including remove and rehang door, adjust stops/ease rebates, remove and refix Ironmongery and redecorate to match existing | IT | 21.38 | read |
| 341101 | Carpentry and joinery | Frame : Renew external door frame with rebated softwood door frame to suit any size single door, remove existing door and set aside, take out existing frame and bed new frame in cement mortar, plugged and screwed to bric | NO | 110.73 | read |
| 341103 | Carpentry and joinery | Frame : Renew extemal door frame with rebated softwood door frame with cill to suit any size single door, remove existing door and set aside, take out existing frame and bed new frame In cement mortar, plugged and screwe | NO | 137.35 | read |
| 341105 | Carpentry and joinery | Frame • Renew external door frame with softwood door frame, rebated and with fanlight over, to suit any size single door, remove existing door and set aside, remove existing frame and bed new frame In mortar, plugged and | NO | 201.49 | read |
| 341201 | Carpentry and joinery | Frame : Renew extemal door frame with any rebated proprietary high performance door frame to suit any size single door, take out existing frame and bed new frame in cement mortar, plugged and screwed to brickwork and poi | NO | 203.85 | read |
| 341203 | Carpentry and joinery | Frame : Renew external door frame with any rebated proprietary high performance door frame with cill to suit any size single door, take out existing frame and bed new frame In cement mortar, plugged and screwed to brickw | NO | 272.57 | read |
| 341205 | Carpentry and joinery | Frame : Renew external door frame with any rebated proprietary high performance door frame and fanlight over, to suit any size single door, remove existing frame and bed new frame in mortar, plugged and screwed to brickw | NO | 305.54 | read |
| 341207 | Carpentry and joinery | Frame : Renew external door frame with any rebated proprietary high performance door frame with cill and fanlight to suit any size single door, remove existing frame and bed new frame in mortar, plugged and screwed to br | NO | 374.26 | inferred |
| 341301 | Carpentry and joinery | Frame : Renew window/door frame unit with standard softwood unit N.E 1.60m wide x 2.10m high including N.E. 2 No. opening lights, factory applied base stain or primer finish, compressible weather-stripping, ironmongery i | IT | 412.45 | inferred |
| 341303 | Carpentry and joinery | Frame : Renew window/door frame unit with standard softwood unit N.E. 2.1 Om wide x 2.10m high Including N.E. 2 No. opening lights, factory applied base stain or primer finish, compressible weather-stripping, Ironmongery | IT | 6.12 | inferred |
| 341305 | Carpentry and joinery | Frame : Renew window/door frame unit with standard softwood unit N.E. 2.70m wide x 2.10m high Including N.E. 2 No opening lights, factory applied base stain or primer finish, compressible weather-stripping, Ironmongery i | IT | 792.64 | read |
| 341501 | Carpentry and joinery | Frame : Renew window/door frame wrth standard hardwood N E. 1.60m wide x 2.10m high including N.E. 2 No. opening lights, factory applied stain or primer finish, compressible weather-stripping, Ironmongery including locki | IT | 678.96 | read |
| 341503 | Carpentry and joinery | Frame : Renew window/door frame unit with standard hardwood unit N.E. 2.10m wide x 2 10m high including N.E. 2 No. opening lights, factory appfied base stain or primer finish, compressible weather-stripping, ironmongery | IT | 865.75 | read |
| 341505 | Carpentry and joinery | Frame: Renew window/door frame unit with standard hardwood unit N.E wide x 2.10m high Including N.E. 2 No. opening lights, factory applied base stain or primer finish, compressible weather-stripping, Ironmongery Includin | IT | 1125.11 | read |
| 341601 | Carpentry and joinery | Frame : Renew window/door frame unit with PVCu factory glazed unit N.E. 1.60m wide x 2.10m high, double glazed internally with 20mm hermetically sealed unit including N.E. 2 No. opening lights, thermal breaks, compressib | IT | 688.26 | read |
| 341603 | Carpentry and joinery | Frame· Renew window/door frame unit with PVCu factory glazed unit N.E. 2.10m wide x 2.1 Om high, double glazed internally with 20mm hermetically sealed unit including N.E. 2 No. opening lights, thermal breaks, compressib | IT | 757.42 | read |
| 341605 | Carpentry and joinery | Frame. Renew window/door frame unit with PVCu factory glazed unit N.E. 2.70m wide x 2.1 Om high, double glazed internally with 20mm hermetically sealed unit including N E. 2 No. opening lights, thermal breaks, compressib | IT | 838.03 | read |
| 341607 | Carpentry and joinery | Frame : Renew screen/door frame/screen unit with PVCu factory glazed combination unit, thermal breaks, compressible weather-stripping, ironmongery etc., fixed lights double glazed with 20mm hermetically sealed units remo | SM | 239.16 | read |
| 341701 | Carpentry and joinery | waterbar . Renew N.E. 914mm long proprietary waterbar screwed to timber or concrete Including plugging and bedded 1n sealant | NO | 10.19 | read |
| 341705 | Carpentry and joinery | waterbar : Lift existing propnetary waterbar, clean end refix, screw to timber and bed In sealant | NO | 5.46 | read |
| 341903 | Carpentry and joinery | Weatherstrip : Renew proprietary rebated weatherstrip to edge of timber door. | NO | 20.35 | read |